La Gard Supra 66E - Electronic Combination Safe Lock

Overview

Safe Lock La Gard - Input unit 3125
Safe Lock La Gard - Input unit 3125

As a furthter development of the AuditGard lock the Supra Series offers beside the base functions an increased number of users. Customised versions have to be created by adding functions via keypad or by using the LA GARD PC programming software.

Different input units - all in metal design - are available with a soft keypad or a foil keypad.

According to the safe application, a deadbolt or a swingbolt locking system can be chosen. The patented swingbolt technology offers a spindle-less system which moves the bolt by the operation of the bolt work.

Features

Approvals / Certificates
EN 1300 B, ECB-S, VdS class 2, DNV, UL type 1
Power supply

1 x 9 volt block battery (not included in delivery) or
6 x 1.5 volt C-cell battery, recommended for time delay (not included in delivery)

External power supply by VdS certified alarm interface

Lock 
Die-cast lock case and bolt, bolt with 2 M4 threads (only for deadbolt)
Incl. 3 screws for lock mounting
Admissible mounting positions 
Deadbolt:
Right hand/left hand lock (upside down mounting), opening clockwise
Mounting position lock - Vertical (bolt up) Mounting position lock - Vertical (bolt down) Mounting position lock - Horizontal (bolt left) Mounting position lock - Horizontal (bolt right)
Swingbolt:
Right hand/left hand lock (upside down mounting, dual-handed)
Mounting position lock - Vertical (bolt up) Mounting position lock - Vertical (bolt down) Mounting position lock - Horizontal (bolt left) Mounting position lock - Horizontal (bolt right)

Technical Data

Input units31253750-K
 Safe Lock La Gard - Input unit 3125 Safe Lock La Gard - Input unit 3750 
Input unitMetal,
satin chrome
Metal,
satin chrome
Battery caseSeparate battery
box*
Integrated,
1 x 9 v block battery*
Key padSiliconeFoil
External power contactYesNo
Cable length457 mm (18”)457 mm (18”)
Spindle length152 mm (6”)152 mm (6”)
Deadbolt availableYesYes
Swingbolt availableYesYes
Order number8285582856

* Not included in delivery

Options input unitsOption code
Die-cast back plate (only for input unit 3125)GZN
Lock Order number
LA GARD 4300M
Swingbolt
Safe Lock La Gard - Lock 4200M 82818
LA GARD 6040M
Deadbolt, throw 8.7 mm
Safe Lock La Gard - Lock 6040M 82815
Options lockOption code
Not grounded
POT
AccessoriesOrder number
Small battery box (1 x 9 volt block battery)82891/0001
Large battery box (6 x 1.5 volt C-cell battery)82891/0004
Small battery/alarm box (1 x 9 volt block battery), required for alarm functions82891/0002
Large battery/alarm box (6 x 1.5 volt C-cell battery), required for alarm functions82891/0006
Wall Plug Transformer 220 volt AC (EU-plug) with battery port connector, without VdS certificate82892/0011
Alarm Interface 871084-2, VdS listed82891/0007
Audit cable (for input unit 3125 only)82892/0002
Audit cable (for input unit 3750-K only)82892/0004
AuditGard Software-Kit (CD with Setup- and AuditView Software / USB-Adapter /
Cable for Entry Device 3125 / Cable for Entry Device 3750-K)
82892/0022
Reset box (necessary to reset the operating mode to works mode)82894/0001
9 volt alkaline block battery0 516 000 000
Screw for Swingbolt lock, 1/4 - 20 x 1.03 PH, with screw locking coating1 269 902 610
Screw for Deadbolt lock, 1/4 - 20 x 1-7/32 PH, with screw locking coating1 269 903 090

Functionality

Codes
1 Master
1 Manager
30 Users
Lock functions

Time Delay 00-99 minutes and opening delay 00-19 minutes configurable

opening delay bypassing (user ID #31)*
Dual Mode*
Time Delay Override*
Add/Delete User code (Manager only)
Enable/Disable User code (Manager only)
Add/Delete Manager code (Master only)
Enable/Disable Manager code (Master only)
Remote disable lock opening (shuts the opening of the lock in spite of a correct code) **/***
Silent Alarm***
Audit (record of the last 512 events)
Master reset (Master and Manager in combination are able to set the lock in the pre-setup mode (factory setting), the whole configuration will be reset here)

* Must be configurated by the initial configuration, subsequently it can just be enable/disable by master reset and reconfiguration

** Activation by PC software required
*** Battery box with alarm function or separate Alarm Interface (VdS listed) required

General functions
Low battery signal
Wrong try lockout after 4 false codes

Documents